Sight Glasses

Ancillary Equipment Sight Glasses T3

Ancillary Equipment Sight Glasses

T3

  • SCCV System
  • Stainless Steel
  • Supports condensate recovery
  • Horizontal installation
  • Vertical installation
  • Bypass function
  • Auto blow-off

    Flapper Type

    Ancillary Equipment Sight Glasses T3

    Features/Applications

    Features

    • Useful for checking condensate flow status

    • The movement of the internal flapper makes it possible to check slight condensate flows

    • Simple maintenance

    Typical applications

    Suitable for the check of steam trap operation.

    (Please install at least 1m away from the outlet of steam trap.)

    Dimensions/Weight

    Dimensions/Weight

    Screwed

    T3_Rc.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H W L H W (kg) (lb)
    1/2” 123 70 115 4.8 2.8 4.5 1,6 3.5
    3/4” 1,7 3.7
    1”
    1 1/4” 170 85 155 6.7 3.3 6.1 3,3 7.3
    1 1/2” 3,2 7.1
    2” 195 115 185 7.7 4.5 7.3 7,3 16.1

     

    Flanged

    T3_FF.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H W L H W (kg) (lb)
    1/2” 144 70 115 5.7 2.8 4.5 3,3 7.3
    3/4” 4,4 9.7
    1” 5,0 11.0
    1 1/4” 180 85 155 7.1 3.3 6.1 8,0 17.6
    1 1/2” 9,0 19.8
    2” 210 115 185 8.3 4.5 7.3 12,0 26.4

    Specifications

    Model Connection

    Max. operating

    pressure

    Max. operating

    pressure differential

    Max. operating

    temperature

    Body

    material

    Type Size PMO(MPa) PMO(psig) (MPa) (psig) TMO(℃) TMO(℉)
    T3

    Screwed

    Rc,NPT

    1/2”

    1,0

    145

    1,0

    145

    183 361

    Cast steel

    WCB

    3/4”
    1”
    1 1/4”
    1 1/2”
    2”

    Cast iron

    FC200

    T3F

    Flanged

    FF,RF*

    1/2” 1,0 145 1,0 145 183 361

    Cast steel

    WCB

    3/4”
    1”
    1 1/4”
    1 1/2”
    2”

    Cast iron

    FC200

    *Can potentially meet these flange standards: JIS 10K, 16K, 20K ASME/JPI 150lb, 300lb *However, it is not possible to manufacture a 50A (2") for ASME/JPI 300lb
    ●Replace the glass, mica plate, and gasket every year.
    ●Install at least 1m from the trap outlet.
    ●Do not use this product with lines in which water hammer occurs.

    Download

    * Membership registration is required to download the documents.

    Features

    • Useful for checking condensate flow status

    • The movement of the internal flapper makes it possible to check slight condensate flows

    • Simple maintenance

    Typical applications

    Suitable for the check of steam trap operation.

    (Please install at least 1m away from the outlet of steam trap.)

    Dimensions/Weight

    Screwed

    T3_Rc.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H W L H W (kg) (lb)
    1/2” 123 70 115 4.8 2.8 4.5 1,6 3.5
    3/4” 1,7 3.7
    1”
    1 1/4” 170 85 155 6.7 3.3 6.1 3,3 7.3
    1 1/2” 3,2 7.1
    2” 195 115 185 7.7 4.5 7.3 7,3 16.1

     

    Flanged

    T3_FF.png

     

    Size Dimensions (mm) Dimensions (in) Weight
    L H W L H W (kg) (lb)
    1/2” 144 70 115 5.7 2.8 4.5 3,3 7.3
    3/4” 4,4 9.7
    1” 5,0 11.0
    1 1/4” 180 85 155 7.1 3.3 6.1 8,0 17.6
    1 1/2” 9,0 19.8
    2” 210 115 185 8.3 4.5 7.3 12,0 26.4
    Model Connection

    Max. operating

    pressure

    Max. operating

    pressure differential

    Max. operating

    temperature

    Body

    material

    Type Size PMO(MPa) PMO(psig) (MPa) (psig) TMO(℃) TMO(℉)
    T3

    Screwed

    Rc,NPT

    1/2”

    1,0

    145

    1,0

    145

    183 361

    Cast steel

    WCB

    3/4”
    1”
    1 1/4”
    1 1/2”
    2”

    Cast iron

    FC200

    T3F

    Flanged

    FF,RF*

    1/2” 1,0 145 1,0 145 183 361

    Cast steel

    WCB

    3/4”
    1”
    1 1/4”
    1 1/2”
    2”

    Cast iron

    FC200

    *Can potentially meet these flange standards: JIS 10K, 16K, 20K ASME/JPI 150lb, 300lb *However, it is not possible to manufacture a 50A (2") for ASME/JPI 300lb
    ●Replace the glass, mica plate, and gasket every year.
    ●Install at least 1m from the trap outlet.
    ●Do not use this product with lines in which water hammer occurs.

    * Membership registration is required to download the documents.

    Contact