Direct Acting for liquids and gases
 
            Pressure Reducing Valves Direct Acting for liquids and gases
REAC20
 
                Features/Applications
Features
- Self-acting pressure reducing valves for liquids and gases- The model REA20 is a direct acting pressure reducing valve designed for compressible media, such as air and various gasses and for incompressible media such as water, oil and others. The valve is self acting and does not require external energy. 
- Wide range of pressure reduction- Due to careffully selected springs an outstanding reduction ratio of 25:1 is achieved. 
- Superb durability- Highly durable and carefully selected components, a 360° free rotating, conical plug and the lack of a sensitive diaphragm ensure outstanding lifetime of this valve. 
- Operating features of direct acting pressure reducing valves- Pressure changes on the downstream side are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to keep the pressure on the downstream side at set pressure. 
- Diaphram free design- The valve operates with an O-ring sealing and a piston design. Due to this design, no daiphragm and no external sensing line is required. 
- Options available- - additional pressure gauges 
 - tailored connections for special applications
 - softsealing for leakage class VI
Typical applications
Ideally installed in any fluid system or technical gases, such as lube oil lines, pre-heater units, natural gas lines, pressurized air lines, LNG or gasoline tank systems. Fits perfectly for other technical gases such as Atzetylene, Ammonia, Carbondioxide.
Dimensions/Weight
Dimensions/Weight

| Size (DN) | Dimension (mm) | Kvs Value | Weight (kg) | |||
| L | H | h | ||||
| PN40 | ||||||
| 15 | 130 | 310 | 90 | 8,0 | 12,5 | |
| 20 | 150 | 11,0 | 12,5 | |||
| 25 | 160 | 12,0 | 13,5 | |||
| 32 | 180 | 330 | 120 | 12,0 | 16,0 | |
| 40 | 200 | 14,0 | 18,5 | |||
| 50 | 230 | 435 | 130 | 63,0 | 32,5 | |
| 65 | 290 | 465 | 155 | 92,0 | 40,0 | |
| 80 | 310 | 630 | 180 | 113,0 | 66,0 | |
| 100 | 350 | 655 | 150,0 | 78,0 | ||
| 125 | 400 | 660 | 210 | 196,0 | 120,0 | |
| 150 | 480 | 680 | 235 | 321,0 | 183,0 | |
| 200 | 600 | 740 | 285 | 483,0 | 358,0 | |
Specifications
| PN40 | |||
| Max. design pressure (MPa) PMA | 4,0 | ||
| Max. design temperature (℃) TMA | 400 | ||
| Max. operating pressure (MPa) PMO | 4,0 | ||
| Max. operating temperature (℃) TMO | 400 | ||
| PN | Temperature℃ | |||||||||||
| -10・・・+50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | |||||
| Pressure MPa | ||||||||||||
| PN40 | 4,0 | 3,7 | 3,4 | 3,1 | 2,9 | 2,8 | 2,7 | 2,6 | ||||
| Secondary pressure range | DN15-DN40 | DN50 | DN65 | DN80 | DN100 | DN125-DN200 | 
| MPa | Spring number per size | |||||
| < 0,05 | On request | On request | ||||
| 0,05-0,1 | 9 | 28 | 27 | 38 | 37 | |
| 0,1-0,16 | 8 | 27 | 26 | 37 | 36 | |
| 0,16-0,25 | 7 | 26 | 25 | 36 | 35 | |
| 0,25-0,4 | 6 | 25 | 24 | 35 | 34 | |
| 0,4-0,63 | 5 | 24 | 23 | 34 | 33 | |
| 0,63-1,0 | 4 | 23 | 22 | 33 | 32 | |
| 1,0-1,6 | 3 | 22 | 21 | 32 | 32 | |
| > 1,6 | On request | |||||
Secondary pressure ranges higher than 1,6 MPa and lower than 0,05 MPa on request available.
Capacity Chart



Download
* Membership registration is required to download the documents.
Features
- Self-acting pressure reducing valves for liquids and gases- The model REA20 is a direct acting pressure reducing valve designed for compressible media, such as air and various gasses and for incompressible media such as water, oil and others. The valve is self acting and does not require external energy. 
- Wide range of pressure reduction- Due to careffully selected springs an outstanding reduction ratio of 25:1 is achieved. 
- Superb durability- Highly durable and carefully selected components, a 360° free rotating, conical plug and the lack of a sensitive diaphragm ensure outstanding lifetime of this valve. 
- Operating features of direct acting pressure reducing valves- Pressure changes on the downstream side are detected in the detection chamber, and the degree of opening of the valve is directly adjusted to keep the pressure on the downstream side at set pressure. 
- Diaphram free design- The valve operates with an O-ring sealing and a piston design. Due to this design, no daiphragm and no external sensing line is required. 
- Options available- - additional pressure gauges 
 - tailored connections for special applications
 - softsealing for leakage class VI
Typical applications
Ideally installed in any fluid system or technical gases, such as lube oil lines, pre-heater units, natural gas lines, pressurized air lines, LNG or gasoline tank systems. Fits perfectly for other technical gases such as Atzetylene, Ammonia, Carbondioxide.
Dimensions/Weight

| Size (DN) | Dimension (mm) | Kvs Value | Weight (kg) | |||
| L | H | h | ||||
| PN40 | ||||||
| 15 | 130 | 310 | 90 | 8,0 | 12,5 | |
| 20 | 150 | 11,0 | 12,5 | |||
| 25 | 160 | 12,0 | 13,5 | |||
| 32 | 180 | 330 | 120 | 12,0 | 16,0 | |
| 40 | 200 | 14,0 | 18,5 | |||
| 50 | 230 | 435 | 130 | 63,0 | 32,5 | |
| 65 | 290 | 465 | 155 | 92,0 | 40,0 | |
| 80 | 310 | 630 | 180 | 113,0 | 66,0 | |
| 100 | 350 | 655 | 150,0 | 78,0 | ||
| 125 | 400 | 660 | 210 | 196,0 | 120,0 | |
| 150 | 480 | 680 | 235 | 321,0 | 183,0 | |
| 200 | 600 | 740 | 285 | 483,0 | 358,0 | |
| PN40 | |||
| Max. design pressure (MPa) PMA | 4,0 | ||
| Max. design temperature (℃) TMA | 400 | ||
| Max. operating pressure (MPa) PMO | 4,0 | ||
| Max. operating temperature (℃) TMO | 400 | ||
| PN | Temperature℃ | |||||||||||
| -10・・・+50 | 100 | 150 | 200 | 250 | 300 | 350 | 400 | |||||
| Pressure MPa | ||||||||||||
| PN40 | 4,0 | 3,7 | 3,4 | 3,1 | 2,9 | 2,8 | 2,7 | 2,6 | ||||
| Secondary pressure range | DN15-DN40 | DN50 | DN65 | DN80 | DN100 | DN125-DN200 | 
| MPa | Spring number per size | |||||
| < 0,05 | On request | On request | ||||
| 0,05-0,1 | 9 | 28 | 27 | 38 | 37 | |
| 0,1-0,16 | 8 | 27 | 26 | 37 | 36 | |
| 0,16-0,25 | 7 | 26 | 25 | 36 | 35 | |
| 0,25-0,4 | 6 | 25 | 24 | 35 | 34 | |
| 0,4-0,63 | 5 | 24 | 23 | 34 | 33 | |
| 0,63-1,0 | 4 | 23 | 22 | 33 | 32 | |
| 1,0-1,6 | 3 | 22 | 21 | 32 | 32 | |
| > 1,6 | On request | |||||
Secondary pressure ranges higher than 1,6 MPa and lower than 0,05 MPa on request available.



* Membership registration is required to download the documents.